Files
dynalab-core/test/test_derive.py
T
h3cx 207a91811e Moved derive unit API to DLUnit
Derived units now use a DLUnit class similar to a DLPak to be easily
stored and loaded, the public API has been updated to either take a
DLUnit object or a Path where it reads the DLUnit from a *.dlunit file

The .dlunit file is a ZIP compressed archive containing two files, a
manifest.json which stores the units uuid, its input signals and its
output signal, and unit.py which is the python code for the unit, the
same rules apply (one python function with a specifically structured
signature) as when a string was passed in the old API

Errors have been added to have a DLUnitError similar to the DLPakError
as the DLUnit class is heavily inspired from the DLPak architecutre

Logging may still be primitive, this will be covered in the next AI
logging sweep to homogenize and clean up the logging aspect of things
2026-09-15 17:13:27 +02:00

129 lines
4.2 KiB
Python

import logging
from queue import Empty, Queue
import time
from uuid import UUID, uuid4
import pytest
from dynalab_core.derive import DeriveRegistry
from dynalab_core.dlunit import DLUnit
from dynalab_core.protocols.packets.data import ValueDescriptor
from dynalab_core.protocols.packets.handshake import SignalDescriptor
PROCESSING_FUNCTION = """
from dynalab_core.protocols.packets.data import ValueDescriptor
from dynalab_core.protocols.packets.handshake import SignalDescriptor
def add(left: ValueDescriptor, right: ValueDescriptor, output: SignalDescriptor) -> ValueDescriptor:
return ValueDescriptor(
signal_id=output.id,
value=left.value + right.value,
timestamp=left.timestamp,
)
"""
FAILING_PROCESSING_FUNCTION = """
from dynalab_core.protocols.packets.data import ValueDescriptor
from dynalab_core.protocols.packets.handshake import SignalDescriptor
def fail(value: ValueDescriptor, output: SignalDescriptor) -> ValueDescriptor:
raise RuntimeError("derive failed")
"""
def make_dlunit(
source: str,
input_signals: list[SignalDescriptor],
return_signal: SignalDescriptor,
) -> DLUnit:
dlunit = DLUnit()
dlunit.set_manifest(uuid4(), input_signals, return_signal)
dlunit.set_data(source)
return dlunit
def test_derive_registry_routes_with_live_values() -> None:
output_queue: Queue[ValueDescriptor] = Queue()
left_signal = SignalDescriptor(id=uuid4(), name="Left", type="number")
right_signal = SignalDescriptor(id=uuid4(), name="Right", type="number")
output_signal = SignalDescriptor(id=uuid4(), name="Total", type="number")
live_values: dict[UUID, ValueDescriptor] = {}
registry = DeriveRegistry(output_queue, live_values.get)
try:
unit = registry.register(
make_dlunit(
PROCESSING_FUNCTION,
[left_signal, right_signal],
output_signal,
)
)
right_value = ValueDescriptor(signal_id=right_signal.id, value=2.0, timestamp=1)
live_values[right_signal.id] = right_value
left_value = ValueDescriptor(signal_id=left_signal.id, value=3.0, timestamp=2)
registry.put_data(left_value)
deadline = time.monotonic() + 1.0
while True:
try:
result = output_queue.get_nowait()
break
except Empty:
if time.monotonic() >= deadline:
raise AssertionError("Derive unit did not produce a value")
time.sleep(0.01)
registry.unregister(unit.uuid())
assert registry.get(unit.uuid()) is None
finally:
registry.stop()
assert result.signal_id == output_signal.id
assert result.value == 5.0
assert result.timestamp == left_value.timestamp
def test_derive_registry_ignores_unknown_unit_on_unregister() -> None:
registry = DeriveRegistry(Queue(), lambda signal_id: None)
try:
registry.unregister(uuid4())
finally:
registry.stop()
def test_derive_worker_logs_failure_and_stops(
caplog: pytest.LogCaptureFixture,
) -> None:
input_signal = SignalDescriptor(id=uuid4(), name="Input", type="number")
output_signal = SignalDescriptor(id=uuid4(), name="Output", type="number")
registry = DeriveRegistry(Queue(), lambda signal_id: None)
with caplog.at_level(logging.DEBUG, logger="dynalab_core"):
try:
unit = registry.register(
make_dlunit(
FAILING_PROCESSING_FUNCTION,
[input_signal],
output_signal,
)
)
unit.put_data(
[ValueDescriptor(signal_id=input_signal.id, value=1.0, timestamp=1)]
)
assert unit._stopped_event.wait(1.0)
assert registry.get_all_signal_descriptors() == []
finally:
registry.stop()
failures = [
record
for record in caplog.records
if getattr(record, "event", None) == "derive.worker_failed"
]
assert len(failures) == 1
assert failures[0].derive_uuid == str(unit.uuid())
assert failures[0].exception_type == "RuntimeError"
assert failures[0].exc_info is not None