4.8 KiB
Ignition Output Module
Purpose
This module drives the existing dual-ended, two-pin dumb ignition coil. The
coil primary is battery-fed and switched on its low side by an STMicroelectronics
VBG08H-E smart ignition IGBT (VBG08HTR-E for tape-and-reel assembly).
The VBG08H-E integrates the ignition IGBT, high-voltage clamp, coil-current limit, thermal protection, soft shutdown, and a coil-current threshold flag. Its 8 A maximum operative coil-current rating is compatible with V1 only after the final coil's primary characteristics and required dwell current are confirmed.
Power path
HVCconnects to one coil-primary terminal; the other terminal connects toVBAT_PROT.VSis supplied fromVBAT_PROT. Place a 100 nF ceramic and 10 µF local capacitor atVS, following the VBG08H-E reference circuit.VBAT_PROTprotection must maintain the VBG08H-E within its 5.4-28 V operating supply range during normal operation and expected local transients.- Do not place a conventional flyback diode across the coil primary. The VBG08H-E's internal high-voltage clamp provides the rapid primary-current collapse required to generate a spark.
Command and inhibit path
INP is active high: a rising edge begins coil dwell and a falling edge
causes the normal spark event.
The VBG08H-E input-high requirement is 3 V. A 5 V buffer is used rather than direct STM32 drive to preserve high-level margin across MCU output tolerance, temperature, and ignition noise.
EN is active low:
SAFE_IGNITION_INHIBIT = NOT(ENGINE_PERMIT)
When ENGINE_PERMIT is removed by the two-channel deadman interlock or the
MCU, SAFE_IGNITION_INHIBIT becomes high. If a dwell is active, this invokes
the VBG08H-E soft shutdown so coil current is removed without intentionally
generating a spark. The 1 kOhm resistors on INP and EN follow the
manufacturer's reference circuit and limit transient current into the device's
control pins.
The command traces shall be short, have a continuous quiet reference, and be
routed away from the HVC switching node and coil connector. The VBG08H-E
already includes input filtering; no external RC filter shall be added until
its timing effect has been analysed.
Fit a low-capacitance Zener clamp directly at each INP and EN power-IC pin,
on the VBG side of its 1 kOhm series resistor. Each clamp returns to the VBG
local Kelvin-ground reference at the IGN_PGND joining point, not to remote
DGND. The clamp voltage shall tolerate the valid 5 V logic high while
limiting positive transients before the VBG08H-E input-overvoltage threshold.
On EN, the protection network must preserve the fail-safe high/inhibit state
and must not create a path that can pull EN low during a fault.
Current-flag diagnostic
C.F. is an open-drain output. It is low while coil current is below its
internal threshold and releases when the current reaches the nominal 6.5 A
threshold. The threshold is not externally programmable.
The pull-up voltage must not exceed 5.5 V; +3V3_MAIN is suitable. The signal
is a diagnostic confirmation of primary-current buildup and is not part of the
hardware ignition shutoff path. Firmware shall use it to detect and report an
under-current/late-current condition while retaining a separately defined
maximum dwell time.
Ground and layout
Define IGN_PGND as the ignition module's high-current return domain.
PGND1andPGND2must use equal-length, equal-width, and similarly shaped copper paths to theIGN_PGNDjoining point. The VBG08H-E uses these paths in its internal current-sensing scheme; imbalance shifts its current limit and current-flag threshold.- The VBG08H-E
GNDpin connects locally to that same joining point through a short, separate Kelvin/reference trace. It does not carry coil current. - Do not separately connect the VBG08H-E
GNDpin to the remoteDGNDplane.IGN_PGNDandDGNDmeet only at the deliberate power-entry ground star, preventing parallel ground-return paths. - Keep the coil-current loop compact and isolate its routing from MCU, ADC, trigger-input, and communication traces.
Remaining validation before schematic freeze
- Identify the coil and measure/obtain its primary resistance, inductance, operating current, and permitted dwell characteristics.
- Confirm that worst-case stored energy and current remain within the VBG08H-E repetitive operating limits at the 16.8 V battery maximum.
- Verify thermal performance with the selected PCB copper area and enclosure.
- Validate spark noise,