Reviewd and fixed deadman architecture

This commit is contained in:
2026-09-10 23:53:27 +02:00
parent 31b3595ac0
commit f8d111ef5c
15 changed files with 304 additions and 305 deletions
+2 -2
View File
@@ -7,9 +7,9 @@ NeoECU V1. It accepts externally driven 5 V, 12 V, and protected
battery-domain signals, plus dry-contact and open-collector sources when the
appropriate ECU bias option is fitted.
This is not the crank/cam trigger interface and is not either deadman
This is not the crank/cam trigger interface and is not the dedicated deadman
engine-permit input. Those functions retain their dedicated conditioning and,
for the deadman, its independent two-channel hardware safety path defined in
for the deadman, its single-input hardware permission path defined in
[DEAD_MAN.md](DEAD_MAN.md).
V1 provisionally allocates six generic digital-input channels. The allocation,